Compile
This chapter describes how to compile COBOL programs using GnuCOBOL.
Compiler options
The compiler cobc accepts the options described in this section. The compiler arguments follow the general syntax cobc options file [file …]. A complete list of options can be displayed by using the option --help.
Help options
The following switches display information about the compiler:
--help, -h-
Display help screen (see Appendix A). No further actions will be taken.
--version, -V-
Display compiler version, author package date and executable build date. No further actions will be taken.
-dumpversion-
Display internal compiler version (plain string of numbers). No further actions will be taken.
--info-
Display build information along with the default and current compiler configurations. No further actions will be taken except for further display options.
--verbose, -v-
Verbosely display the programs invoked during compilation and additional diagnostics. Use multiple times to increase the verbosity.
--list-reserved-
Display reserved words (see Appendix B). A Yes/No output shows if the word is supported 1, context sensitive and its aliases. The given options for reserved words specified for example by option
-std=dialectwill be taken into account. No further actions will be taken except for further display options. --list-intrinsics-
Display intrinsic functions (see Appendix C). A Y/N field shows if the function is implemented. No further actions will be taken except for further display options.
--list-system-
Display system routines (see Appendix D). No further actions will be taken except for further display options.
--list-mnemonics-
Display mnemonic names (see Appendix E). No further actions will be taken except for further display options.
--list-exceptions-
Display exception names (see Appendix F). No further actions will be taken except for further display options.
Build target
The compiler cobc treats files like *.cob, *.cbl as COBOL source code, *.c as C source code, *.o as object code, *.i as preprocessed code and *.so as dynamic modules and knows how to handle such files in the generation, compilation, and linking steps.
The special input name - takes input from stdin which is assumed to be COBOL source, and uses a default output name of a.out (or a.so/c/o/i, selected as appropriate) for the build type.
You may also use - as output name for the listing file or the preprocessor result, for example with cobc -t - prog.cob / cobc -P- prog.cob.
By default, the compiler builds a dynamically loadable module.
The following options specify the target type produced by the compiler:
-E-
Preprocess only: compiler directives are executed, comment lines are removed, and
COPYandREPLACEstatements are performed. The output is sent to stdout, allowing you to directly use it as input for another process. You can manually set an output file using-o. --copy copybook-
Include
copybookat the beginning of the source code, as ifCOPY copybookhad been parsed. --include file.h-
Add a
#includefile.hat the beginning of the generated C source file. The file name is put into quotes, unless it starts by<. Quoted files should be absolute paths, since C files are compiled in temporary directories. The directive>>IMP INCLUDE "FILE.h"or>>IMP INCLUDE <FILE.h>can be used as an alternative to this compiler option. The option also implies-fno-gen-c-decl-static-call. This option can be used to check function prototypes when static calls are used. When this option is used, the source file is compiled in the project directory (instead of the temp directory), and no prototypes are generated, so ALL static call functions must appear in the header file, with GnuCOBOL compatible types. -C-
Translation only. COBOL source files are translated into C files. The output is saved in file
*.c. --save-temps-
Normal compilation with additional storing the preprocessed files as
*.iand the translated C files as file*.c. -S-
Compile only. Translated C files are compiled by the C compiler to assembler code. The output is saved in file
*.s. -c-
Compile and assemble. This is equivalent to
cc -c. The output is saved in file*.o. -m-
Compile, assemble, and build a dynamically loadable module (i.e., a shared library). The output is saved in file
*.so. 2 This is the default behaviour. -b-
Compile, assemble, and combine all input files into a single dynamically loadable module. Unless
-ois also used, the output is saved using the first filename as*.so. -x-
Include the main function in the output, creating an executable image. The main entry point being the first program in the file.
This option takes effect at the translation stage. If you give this option with
-C, you will see the main function at the end of the generated C file. -j, -job, -j=args, -job=args-
Run job after compilation. Either from executable with
-x, or withcobcrunwhen compiling a module. Optional arguments <args>, if given, are passed to the program or module command line. -I directory-
Add <directory> to copy/include search path.
-L directory-
Add <directory> to library search path.
-l lib-
Link the library <lib>.
-D define-
Pass <define> to the COBOL compiler.
-o file-
Place the output into <file>.
Source format
GnuCOBOL supports fixed, free, Micro Focus’ Variable, X/Open Free-form, ICOBOL xCard and Free-form, ACUCOBOL-GT Terminal, and COBOLX source formats. By default, the compiler tries to autodetect the format using the indicator on the first line, using the fixed format for correct indicators and the free format for incorrect ones. This can be overridden either by the >>SOURCE [FORMAT] [IS] {FIXED|FREE|COBOL85|VARIABLE|XOPEN|XCARD|CRT|TERMINAL|COBOLX|AUTO} directive, or by one of the following options:
-free, -F, -fformat=free-
Free format. The program-text area starts in column 1 and continues till the end of line (effectively 255 characters in GnuCOBOL).
-fixed, -fformat=fixed-
Fixed format. Source code is divided into: columns 1-6, the sequence number area; column 7, the indicator area; columns 8-72, the program-text area; and columns 72-80 as the reference area.3
-fformat=cobol85-
Fixed format with enforcements on the use of Area A.
-fformat=variable-
Micro Focus’ Variable format. Identical to the fixed format above except for the program-text area which extends up to column 250 instead of 72.
-fformat=xcard-
ICOBOL xCard format. Variable format with right margin set at column 255 instead of 250.
-fformat=xopen-
X/Open Free-form format. The program-text area may start in column 1 unless an indicator is present, and lines may contain up to 255 characters. Indicator for debugging lines is ‘
D’ (D followed by a space) instead of ‘D’ or ‘d’. -fformat=crt-
ICOBOL Free-form format (CRT). Similar to the X/Open format above, with lines containing up to 320 characters and single-character debugging line indicators (‘
D’ or ‘d’). -fformat=terminal-
ACUCOBOL-GT Terminal format. Similar to the CRT format above, with indicator for debugging lines being ‘
\D’ instead of ‘D’ or ‘d’. This format is mostly compatible with VAX COBOL terminal source format. -fformat=cobolx-
COBOLX format. This format is similar to the CRT format above, except that the indicator area is always present in column 1; the program-text area starts in column 2 and extends up to the end of the record. Lines may contain up to 255 characters.
-fformat=auto-
Autodetection of format. The compiler will use the first line of the file to detect whether the file is in fixed format (with a correct indicator at position 7), or in free format.
Note that with source formats XOPEN, CRT, TERMINAL, and COBOLX, missing spaces are not inserted within continued alphanumeric literals that are truncated before the right margin.
Area A denotes the source code that spans between margin A and margin B, and Area B spans from the latter to the end of the record. Area A enforcement checks the contents of Area A, and reports any item that does not belong to the correct Area: this feature helps in developping COBOL programs that are portable to actual mainframe environments.
In general, division, section, and paragraph names must start in Area A. In the DATA DIVISION, level numbers ‘01’ and ‘77’, must also start in Area A. In the PROCEDURE DIVISIONs, statements and separator periods must fit within Area B. Every source format listed above may be subject to Area A enforcement, except FIXED, FREE, and XOPEN.
Note that Area A enforcement enables recovery from missing periods between paragraphs and sections.
Warning options
Warnings are diagnostic messages that report constructions that are not inherently erroneous but that are risky or suggest there may have been an error.
The following options do not enable specific warnings but control the kinds of diagnostics produced by cobc.
-fsyntax-only-
Check Check the code for syntax errors, but don’t do anything beyond that.
-fmax-errors=n-
Limits the maximum number of error messages to <n>, at which point
cobcbails out rather than attempting to continue processing the source code. If <n> is 0, there is no limit on the number of error messages produced. If-Wfatal-errorsis also specified, then-Wfatal-errorstakes precedence over this option. -w-
Inhibit all warning messages.
-Werror-
Make all warnings into errors.
-Werror=warning-
Make the specified <warning> into an error. The specifier for a warning is appended; for example
-Werror=obsoleteturns the warnings controlled by-Wobsoleteinto errors. This switch takes a negative form, to be used to negate-Werrorfor specific warnings; for example-Wno-error=obsoletemakes-Wobsoletewarnings not be errors, even when-Werroris in effect.The warning message for each controllable warning includes the option that controls the warning. That option can then be used with
-Werror=and-Wno-error=as described above. (Printing of the option in the warning message can be disabled using the-fno-diagnostics-show-optionflag.)Note that specifying
-Werror=fooautomatically implies-Wfoo. However,-Wno-error=foodoes not imply anything. -Wfatal-errors-
This option causes the compiler to abort compilation on the first error occurred rather than trying to keep going and printing further error messages.
You can request many specific warnings with options beginning with ‘-W’, for example -Wimplicit-define to request warnings on implicit declarations. Each of these specific warning options also has a negative form beginning ‘-Wno’ to turn off warnings; for example, -Wno-implicit-define. This manual lists only one of the two forms, whichever is not the default.
Some options, such as -Wall and -Wextra, turn on other options, such as -Wtruncate. The combined effect of positive and negative forms is that more specific options have priority over less specific ones, independently of their position in the command-line. For options of the same specificity, the last one takes effect.
-Wall-
Enable all the warnings about constructions that some users consider questionable, and that are easy to avoid (or modify to prevent the warning). The list of warning flags turned on by this option is shown in
--help. -Wextra, -W-
Enable every possible warning that is not dialect specific. This includes more information than
-Wallwould normally provide. (This option used to be called-W. The older name is still supported, but the newer name is more descriptive.) -Wwarning-
Enable single warning <warning>.
-Wno-warning-
Disable single warning <warning>.
-Warchaic-
Warn if archaic features are used, such as continuation lines or the
NEXT SENTENCEstatement. -Wcall-params-
Warn if non-01/77-level items are used as arguments in a
CALLstatement. This is not set with-Wall. -Wcolumn-overflow-
Warn if text after column 72 in FIXED format. This is not set with
-Wall. -Wconstant-
Warn inconsistent constant
-Wimplicit-define-
Warn if implicitly defined data items are used.
-Wlinkage-
Warn dangling
LINKAGEitems. This is not set with-Wall. -Wobsolete-
Warn if obsolete features are used.
-Wparentheses-
Warn about any lack of parentheses around
ANDwithinOR. -Wredefinition-
Warn about incompatible redefinitions of data items.
-Wstrict-typing-
Warn about type mismatch strictly.
-Wterminator-
Warn about the lack of scope terminator END-XXX. This is not set with
-Wall. -Wtruncate-
Warn on possible field truncation. This is not set with
-Wall.
-Wconstant-expression
-Wconstant-numlit-expression-
Warn about expressions that always resolve to true/false and therefore lead to unreachable code.
-Wunreachable-
Warn if statements are likely unreachable. This is not set with
-Wall. -Wadditional-
Enable warnings that don’t have an own warning flag.
Diagnostics options
The compiler provides some options to tune the way errors and warnings (diagnostics) are displayed to the user.
-fdiagnostics-absolute-paths-
Print absolute paths in diagnostics. This option can be useful if your editor is not able to correctly locate relative paths in your project.
-fdiagnostics-plain-output-
Make diagnostic output as plain as possible.
-fno-diagnostics-show-option-
Suppress output of option that directly controls the diagnostic, on which warnings should be displayed.
-fno-diagnostics-show-caret-
Do not display source context on warning/error diagnostic. By default, diagnostics contain an excerpt with two lines before and after the location.
-fno-diagnostics-show-line-numbers-
Suppress display of line numbers in the source context in diagnostics
Configuration options
The compiler uses many dialect specific options. These may be set via a defined dialect by -std=, a configuration file by -conf= or by using the single dialect flags directly.
See Compiler Configuration, and config/*.conf.
Note concerning the defined dialects: The GnuCOBOL compiler tries to limit both the feature-set and reserved words to the specified compiler when the "strict" dialects are used. COBOL sources compiled with these dialects are therefore likely to compile with the specified compiler and vice versa: sources that were compiled on the specified compiler should compile without any issues with GnuCOBOL. With the "non-strict" dialects GnuCOBOL will activate the complete feature-set where it doesn’t directly conflict with the specified dialect, including reserved words. COBOL sources compiled with these dialects therefore may work only with GnuCOBOL. COBOL sources may need a change because of reserved words in GnuCOBOL, otherwise offending words <word-1> and <word-2> may be removed by -fno-reserved=word-1,word-1.
The dialects COBOL-85, X/Open COBOL, COBOL 2002 and COBOL 2014 are always "strict".
-std=dialect-
Compiler uses the given <dialect> to determine certain compiler features and warnings.
-std=default-
GnuCOBOL dialect, supporting many of the COBOL 2002 and COBOL 2014 features, many extensions found in other dialects and its own feature-set
-std=cobol85-
COBOL-85 without any extensions other than the amendment Intrinsic Function Module (1989), source compiled with this dialect is likely to compile with most COBOL compilers
-std=xopen-
X/Open COBOL (based on COBOL-85) without any vendor extensions, source compiled with this dialect is likely to compile with most COBOL compilers; will warn items that "should not be used in a conforming X/Open COBOL source program"
-std=cobol2002, -std=cobol2014-
COBOL 2002 / COBOL 2014 without any vendor extensions, use
-Warchaicand-Wobsoleteif archaic/obsolete features should be flagged -std=ibm-strict, -std=ibm-
IBM compatible
-std=mvs-strict, -std=mvs-
MVS compatible
-std=mf-strict, -std=mf-
Micro Focus compatible
-std=bs2000-strict, -std=bs2000-
BS2000 compatible
-std=acu-strict, -std=acu-
ACUCOBOL-GT compatible
-std=rm-strict, -std=rm-
RM/COBOL compatible
-std=realia-strict, -std=realia-
CA Realia II compatible
-std=gcos-strict, -std=gcos-
GCOS compatible
-freserved-words=dialect-
Compiler uses the given <dialect> to determine the reserved words.
-conf=<file>-
User-defined dialect configuration.
-febcdic-table=cconv-table/file-
EBCDIC/ASCII translation table to use; either read from <file>, or one of the existing <cconv-table> from the configuration directory (see
cobc --info) which have a .ttbl extension, for example-febcdic-table=alternate. See thedefault.ttblfile for detailed information about the format. You may use the--gentableoption to build such tables. Note that this option may affect LOW/HIGH-VALUE if using a non-native program collating sequence.
You can override each single configuration entry by using compiler configuration options on the command line.
Examples:
-frelax-syntax-checks
-frenames-uncommon-levels=warning
-fnot-reserved=CHAIN,SCREEN
-ftab-width=4
Listing options
-t=file-
Generate and place the standard print listing into
file. -T=file-
Generate and place a wide print listing into
*file. --tlines=lines-
Specify lines per page in print listing, default = 55. Set to zero for no additional page breaks.
-ftsymbols-
Generate symbol table in listing.
-fno-theader-
Suppress all headers from listing while keeping page breaks.
-fno-tmessages-
Suppress warning and error summary from listing.
-fno-tsource-
Suppress actual source from listing (for example to only produce the cross-reference).
-P, -Pdirectory, -P=file-
Generate and place a preprocessed listing (old format) into
filename.lst,directory/filename.lst,file.
-Xref
-X-
Generate cross reference in the listing.
Here is an example program listing with the options -t -ftsymbols:
GnuCOBOL 3.0.0 test.cbl Mon May 14 10:23:45 2018 Page 0001
LINE PG/LN A...B...........................................................
000001 IDENTIFICATION DIVISION.
000002 PROGRAM-ID. prog.
000003 ENVIRONMENT DIVISION.
000004 CONFIGURATION SECTION.
000005 DATA DIVISION.
000006 WORKING-STORAGE SECTION.
000007 COPY 'values.cpy'.
000001C 78 I VALUE 20.
000002C 78 J VALUE 5000.
000003C 78 M VALUE 5.
000008 01 SETUP-REC.
000009 05 FL1 PIC X(04).
000010 05 FL2 PIC ZZZZZ.
000011 05 FL3 PIC 9(04).
000012 05 FL4 PIC 9(08) COMP.
000013 05 FL5 PIC 9(04) COMP-4.
000014 05 FL6 PIC Z,ZZZ.99.
000015 05 FL7 PIC S9(05) SIGN LEADING SEPARATE.
000016 05 FL8 PIC X(04).
000017 05 FL9 REDEFINES FL8 PIC 9(04).
000018 05 FLA.
000019 10 FLB OCCURS I TIMES.
000020 15 FLC PIC X(02).
000021 10 FLD PIC X(20).
000022 05 FLD1 PIC X(100).
000023 05 FLD2 OCCURS M TO J TIMES DEPENDING ON FL5.
000024 10 FILLER PIC X(01).
000025 05 FLD3 PIC X(3).
000026 05 FLD4 PIC X(4).
000027 PROCEDURE DIVISION.
000028 STOP RUN.
The first part of the listing lists the program text. If the program text is a COPY the line number reflects the COPY line number and is appended with a ‘C’.
When the wide list option -T is specified, the SEQUENCE columns (for fixed-form reference-format) are included in the listing.
The second part of the listing file is the listing of the Symbol Table:
GnuCOBOL 3.0.0 test.cbl Mon May 14 10:23:45 2018 Page 0002
SIZE TYPE LVL NAME PICTURE
5204 GROUP 01 SETUP-REC
0004 ALPHANUMERIC 05 FL1 X(04)
0005 ALPHANUMERIC 05 FL2 ZZZZZ
0004 ALPHANUMERIC 05 FL3 9(04)
0004 NUMERIC 05 FL4 9(08) COMP
0002 NUMERIC 05 FL5 9(04) COMP
0008 ALPHANUMERIC 05 FL6 Z,ZZZ.99
0006 ALPHANUMERIC 05 FL7 S9(05)
0004 ALPHANUMERIC 05 FL8 X(04)
0004 ALPHANUMERIC-R 05 FL9 9(04)
0060 ALPHANUMERIC 05 FLA
0040 ALPHANUMERIC 10 FLB OCCURS 20
0002 ALPHANUMERIC 15 FLC X(02)
0020 ALPHANUMERIC 10 FLD X(20)
0100 ALPHANUMERIC 05 FLD1 X(100)
5000 ALPHANUMERIC 05 FLD2 OCCURS 5 TO 5000
0001 ALPHANUMERIC 10 FILLER X(01)
0003 ALPHANUMERIC 05 FLD3 X(3)
0004 ALPHANUMERIC 05 FLD4 X(4)
If the symbol redefines another variable the TYPE is marked with ‘R’. If the symbol is an array the OCCURS phrase is in the PICTURE field.
The last part of the listing file is the summary of warnings an error in the compilation group:
0 warnings in compilation group
2 errors in compilation group
Debug switches
-g-
Produce C debugging information in the output.
--debug, -d-
Enable all run-time error checks.
-fmemory-check=scope-
Enable checking of internal storage during CALL (implied by
--debug. -fec=exception-name, -fno=ec=exception-name-
Enable/disable specified exception checks, see Exception Names;
--debugimplies-fec=ALL. -fsource-location-
Generate source location code (implied by
--debug,-fdumpand-fec). -fstack-check-
Enable
PERFORMstack checking (implied by--debugor-g). -ftrace-
Generate trace code (log executed procedures, if tracing is enabled).
-ftraceall-
Generate trace code (log executed procedures and statements, if tracing is enabled).
-fdebugging-line-
Enable debugging lines (‘
D’ in indicator column; ‘>>D’ directive). -O-
Enable optimization of code size and execution speed. See your C compiler documentation, for example
man gccfor details. -O2-
Optimize even more.
-Os-
Optimize for size. Optimizer will favour code size over execution speed.
-fnotrunc-
Do not truncate binary fields according to PICTURE.
Automatic Prerequisites
Dependencies are files containing the content included by COPY statements. These options are usually used by build systems to extract dependencies from COBOL files. The dependencies can then be used to decide when a file should be recompiled or not.
-M-
Output dependency list in Makefile format on stdout. Stop after preprocessing the file and do not generate any other files.
-MT <target>-
Set/add target file used in dependency list
-MQ <target>-
Same as -MT but with Makefile-quoting of the target
-MF <file>-
Specify a filename <file> where to output dependencies
-MP-
Create phony targets for all dependencies
-MG-
Output missing dependencies without complaining
-MD-
Output dependencies in .d files while compiling
Miscellaneous
-ext <extension>-
Add default file extension.
-fintrinsics=[ALL|intrinsic function name(,name,...)]-
Allow use of all or specific intrinsic functions without
FUNCTIONkeyword.Note: defining this within your source with
CONFIGURATION SECTION. REPOSITORY.is preferred. -ffold-copy=LOWER-
Fold
COPYsubject to lower case (default no transformation). -ffold-copy=UPPER-
Fold
COPYsubject to upper case (default no transformation). -save-temps(=<dir>)-
Save intermediate files (by default, in current directory).
-fimplicit-init-
Do automatic initialization of the COBOL runtime system.
--gentable=ebcdic-enc,ascii-enc[+]-
Build an EBCDIC/ASCII translation table between <ebcdic-enc> and <ascii-enc>, and exit. The translation might not be reversible: characters with no equivalent in the other encoding are mapped to the substitution character, thus leaving unused characters in both encodings. Append + to make the translation reversible, by arbitrarily mapping together these unused characters.
Multiple sources
This section describes how to compile a program from multiple source files.
This section also describes how to build a shared library that can be used by any COBOL program and how to use external libraries in COBOL programs.
Static linking
The easiest way of combining multiple files is to compile them into a single executable.
One way is to compile all the files in one command:
$ cobc -x -o prog main.cob subr1.cob subr2.cob
Another way is to compile each file with the option -c, and link them at the end. The top-level program must be compiled with the option -x.
$ cobc -c subr1.cob
$ cobc -c subr2.cob
$ cobc -c -x main.cob
$ cobc -x -o prog main.o subr1.o subr2.o
You can link C routines as well using either method:
$ cobc -o prog main.cob subrs.c
or
$ cobc -c subrs.c
$ cobc -c -x main.cob
$ cobc -x -o prog main.o subrs.o
Any number of functions can be contained in a single C file.
The linked programs will be called dynamically; that is, the symbol will be resolved at run time. For example, the following COBOL statement
CALL "subr" USING X.
will be converted into equivalent C code like this:
int (*func)() = cob_resolve("subr");
if (func != NULL)
func (X);
With the compiler option -fstatic-call, more efficient code will be generated:
subr(X);
Please notice that this option only takes effect when the called program name is in a literal (like CALL "subr"). With a data name (like CALL SUBR), the program is still called dynamically.
Dynamic linking
There are two methods to achieve this: a driver program, or compiling the main program and subprograms separately.
Driver program
Compile all programs with the option -m:
$ cobc -m main.cob subr.cob
This creates the shared object files main.so and subr.so. 4
Before running the main program, install the module files in your library directory:
$ cp subr.so /your/cobol/lib
Set the runtime variable COB_LIBRARY_PATH to your library directory, and run the main program:
$ export COB_LIBRARY_PATH=/your/cobol/lib
(Please notice: You may set the variable via a runtime configuration file, see Runtime Configuration. You may also set the variable to directly point to the directory where you compiled the sources.)
Now execute your program:
$ cobcrun main
Compiling programs separately
The main program is compiled as usual:
$ cobc -x -o main main.cob
Subprograms are compiled with the option -m:
$ cobc -m subr.cob
This creates a module file subr.so5.
Before running the main program, install the module files in your library directory:
$ cp subr.so /your/cobol/lib
Now, set the environment variable COB_LIBRARY_PATH to your library directory, and run the main program:
$ export COB_LIBRARY_PATH=/your/cobol/lib
$ ./main
Building library
You can build a shared library by combining multiple COBOL programs and even C routines:
$ cobc -c subr1.cob
$ cobc -c subr2.cob
$ cc -c subr3.c
$ cc -shared -o libsubrs.so subr1.o subr2.o subr3.o
Using library
You can use a shared library by linking it with your main program.
Before linking the library, install it in your system library directory:
$ cp libsubrs.so /usr/lib
or install it somewhere else and set LD_LIBRARY_PATH:
$ cp libsubrs.so /your/cobol/lib
$ export LD_LIBRARY_PATH=/your/cobol/lib
Then, compile the main program, linking the library as follows:
$ cobc -x main.cob -L/your/cobol/lib -lsubrs
C interface
This chapter describes how to combine C programs with COBOL programs.
Writing Main Program in C
Include libcob.h in your C program and call cob_init before using any COBOL module. Do a cleanup afterwards, either by calling cob_stop_run (if your program should terminate) or by calling cob_tidy (if your program should execute further on without any more COBOL calls). Calling cob_init, one or several GnuCOBOL modules and then cob_tidy in this sequence can be done multiple times).
#include <libcob.h>
int
main (int argc, char **argv)
{
/* initialize your program */
...
/* initialize the COBOL run-time library */
cob_init (argc, argv);
/* rest of your program */
...
/* Clean up and terminate - This does not return */
cob_stop_run (return_status);
}
You can write cobc_init(0, NULL); if you do not want to pass command line arguments to COBOL.
You can compile your C program as follows:
cc -c ̀cob-config --cflags̀ main.c
The compiled object must be linked with libcob as follows:
cc -o main main.o ̀cob-config --libs̀
Static linking with COBOL programs
Let’s call the following COBOL module from a C program:
---- say.cob ---------------------------
IDENTIFICATION DIVISION.
PROGRAM-ID. say.
ENVIRONMENT DIVISION.
DATA DIVISION.
LINKAGE SECTION.
01 hello PIC X(7).
01 world PIC X(6).
PROCEDURE DIVISION USING hello world.
DISPLAY hello world.
GOBACK.
----------------------------------------
This program accepts two arguments, displays them, and exits.
From the viewpoint of C, this is equivalent to a function having the following prototype:
extern int say(char *hello, char *world);
So, your main program will look like as follows:
---- hello.c ---------------------------
#include <libcob.h>
extern int say(char *hello, char *world);
int
main()
{
int ret;
char hello[8] = "Hello, ";
char world[7] = "world!";
/* initialize the COBOL run-time library */
cob_init(0, NULL);
/* call the static module and store its return code */
ret = say(hello, world);
/* shutdown the COBOL run-time library, keep program running */
(void)cob_tidy();
return ret;
}
----------------------------------------
Compile and run these programs as follows:
$ cobc -x hello.c say.cob
$ ./hello
Hello, world!
or, more split and directly using the C compiler:
$ cc -c `cob-config --cflags` hello.c
$ cobc -c -static say.cob
$ cobc -x -o hello hello.o say.o
$ ./hello
Hello, world!
Note: The biggest benefits of static linking are that all programs are verified to be available in the resulting binary. Furthermore there is a slightly performance benefit in this type of CALL (not visible for "normal" programs).
Dynamic linking with COBOL programs
You can find a COBOL module having a specific name by using the C function cob_resolve, which takes the module name as a string and returns a pointer to the module function.
cob_resolve returns NULL if there is no module. In this case, the function cob_resolve_error returns the error message.
Let’s see an example:
---- hello-dynamic.c -------------------
#include <libcob.h>
static int (*say)(char *hello, char *world);
int main()
{
int ret;
char hello[8] = "Hello, ";
char world[7] = "world!";
/* initialize the COBOL run-time library */
cob_init(0, NULL);
/* Find the module with PROGRAM-ID "say". */
say = cob_resolve("say");
/* If there is no such module, show error and exit. */
if(say == NULL) {
fprintf(stderr, "%s\n", cob_resolve_error());
exit(1);
}
/* Call the module found ... */
ret = say(hello, world);
/* ...and exit with the return code. */
cob_stop_run(ret);
}
----------------------------------------
Compile and run these programs as follows:
$ cobc -x -o hello hello-dynamic.c
$ cobc -m say.cob
$ export COB_LIBRARY_PATH=.
$ ./hello
Hello, world!
The check of the module load as written above can be directly done in libcob as follows:
---- hello-dynamic2.c ------------------
#include <libcob.h>
int main()
{
int ret;
char hello[8] = "Hello, ";
char world[7] = "world!";
void *cob_argv[2];
cob_argv[0] = hello;
cob_argv[1] = world;
/* initialize the COBOL run-time library */
cob_init(0, NULL);
/* do a CALL, expecting the module to exist,
otherwise exiting with an error. */
ret = cob_call ("say", 2, cob_argv);
/* ...and exit with the return code. */
cob_stop_run(ret);
}
----------------------------------------
In any case be aware that all errors that happen within COBOL will exit your program, as same as a STOP RUN will do.
Depending on the application you possibly want to register C signal handlers; error and/or exit handlers in C and/or COBOL to do cleanups, logging or anything else.
There is one way to handle all these scenarios with a call, too, using cob_call_with_exception_check instead of cob_call as follows:
---- hello-dynamic3.c ------------------
#include <libcob.h>
int main()
{
int ret;
char hello[8] = "Hello, ";
char world[7] = "world!";
void *cob_argv[2];
cob_argv[0] = hello;
cob_argv[1] = world;
/* initialize the COBOL run-time library */
cob_init(0, NULL);
/* do a CALL, catching all possible results, */
ret = cob_call_with_exception_check ("say", 2, cob_argv);
switch (ret) {
case 0: /* program coming back */
/* Clean up and terminate runtime */
cob_runtime_hint("program exited with return code %d",
cob_last_exit_code ());
cob_tidy ();
break;
case 1: /* normal exit */
cob_runtime_hint("STOP RUN with return code %d",
cob_last_exit_code ());
break;
case -1: /* error exit */
cob_runtime_hint("error exit with return code %d and error \"%s\"",
cob_last_exit_code (), cob_last_runtime_error ());
break;
case -2: /* hard error exit */
cob_runtime_hint("hard error exit with return code %d and error \"%s\"",
cob_last_exit_code (), cob_last_runtime_error ());
break;
case -3: /* signal handler exit */
cob_runtime_hint("signal handler exit with signal %d and error \"%s\"",
cob_last_exit_code (), cob_last_runtime_error ());
break;
default:
cob_runtime_hint("unexpected return from cob_call_with_exception_check,"
" last exit code %d, last error \"%s\"",
cob_last_exit_code (), cob_last_runtime_error ());
break;
}
/* ...and exit with zero if no error happened */
exit(ret != 0 && ret != 1);
}
----------------------------------------
Static linking with C programs
Let’s call the following C function from COBOL:
---- say.c -----------------------------
int say(char *hello, char *world)
{
int i;
for(i = 0; i < 7; i++)
putchar(hello[i]);
for(i = 0; i < 6; i++)
putchar(world[i]);
putchar('\n');
return 0;
}
----------------------------------------
This program is equivalent to the program in say.cob above.
Note that, unlike C, the arguments passed from COBOL programs are not terminated by the null character (i.e., ‘\0’).
You can call this function in the same way you call COBOL programs:
---- hello.cob -------------------------
IDENTIFICATION DIVISION.
PROGRAM-ID. hello.
ENVIRONMENT DIVISION.
DATA DIVISION.
WORKING-STORAGE SECTION.
01 hello PIC X(7) VALUE "Hello, ".
01 world PIC X(6) VALUE "world!".
PROCEDURE DIVISION.
CALL "say" USING hello world.
STOP RUN.
----------------------------------------
Compile these programs as follows:
$ cobc -x -o hello -static hello.cob say.c
$ ./hello
Hello, world!
or separate:
$ cc -c say.c
$ cobc -c -static -x hello.cob
$ cobc -x -o hello hello.o say.o
$ ./hello
Hello, world!
Dynamic linking with C programs
You can create a dynamically-linked module from a C program by compiling it with cobc ...
$ cobc -m say.c
$ cobc -x hello.cob
$ export COB_LIBRARY_PATH=.
$ ./hello
Hello, world!
or with most C compilers by passing option -shared to the C compiler:
$ cc -shared -o say.so say.c
$ cobc -x hello.cob
$ export COB_LIBRARY_PATH=.
$ ./hello
Hello, world!
Mind that for COBOL to be able to load the module via CALL the name of the binary must either be identical to the CALL name or the binary containing the entry-point must have been loaded before (by a previous call or COB_PRE_LOAD).
Redirecting output to a (FILE *)
From a module written in C you can call cob_set_runtime_option to set the exact (FILE *) which is used to write trace data to. In common.h is the following:
enum cob_runtime_option_switch {
COB_SET_RUNTIME_TRACE_FILE /* 'p' is FILE * */
COB_SET_RUNTIME_DISPLAY_PRINTER_FILE /* 'p' is FILE * */
COB_SET_RUNTIME_RESCAN_ENV /* rescan environment variables */
COB_SET_RUNTIME_DISPLAY_PUNCH_FILE /* 'p' is FILE * */
COB_SET_RUNTIME_STDIN_FILE /* 'p' is FILE * */
COB_SET_RUNTIME_STDOUT_FILE /* 'p' is FILE * */
COB_SET_RUNTIME_STDERR_FILE /* 'p' is FILE * */
};
COB_EXT_IMPORT void cob_set_runtime_option (enum cob_runtime_option_switch opt, void *p);
So from you C code you can tell the GnuCOBOL runtime to redirect TRACE output by:
cob_set_runtime_option (COB_SET_RUNTIME_TRACE_FILE,
(void*)((FILE*)myfd));
You could also redirect all DISPLAY UPON PRINTER output to a file by:
cob_set_runtime_option (COB_SET_RUNTIME_DISPLAY_PRINTER_FILE,
(void*)((FILE*)myfd));
You could also redirect all DISPLAY UPON SYSPUNCH output to a file by:
cob_set_runtime_option (COB_SET_RUNTIME_DISPLAY_PUNCH_FILE,
(void*)((FILE*)myfd));
You are also able to redirect ACCEPT so that instead of stdin, it reads from a file, by using:
cob_set_runtime_option (COB_SET_RUNTIME_STDIN_FILE,
(void*)((FILE*)myfd));
Likewise, you could also redirect all DISPLAY output that would be normally printed to stdout/stderr, including outputs directly coming from the runtime, to a file by:
cob_set_runtime_option (COB_SET_RUNTIME_STDOUT_FILE,
(void*)((FILE*)myfd));
cob_set_runtime_option (COB_SET_RUNTIME_STDERR_FILE,
(void*)((FILE*)myfd));
Another routine can be used to return the current value of the option.
COB_EXT_IMPORT void *
cob_get_runtime_option (enum cob_runtime_option_switch opt);
Loading EBCDIC/ASCII translation tables (collating sequences)
When an EBCDIC/ASCII translation table is needed (for instance when calling sort functions), you can can call the cob_load_collation function to retrieve such tables:
COB_EXT_IMPORT int
cob_load_collation (const char *col_name,
cob_u8_t *ebcdic_to_ascii,
cob_u8_t *ascii_to_ebcdic)